Back to Top

Hi, Guest!

  LOKASI :  Kota Makassar

Bergabung Selama :

BAGIKAN :   

Bagikan :
  • Kimia Klinik
  • CLINICAL CHEMISTRY RANDOM ACCESS ANALYZER - ELLIPSE - AMS

CLINICAL CHEMISTRY RANDOM ACCESS ANALYZER - ELLIPSE - AMS

Update Terakhir
:
16 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
105 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail CLINICAL CHEMISTRY RANDOM ACCESS ANALYZER - ELLIPSE - AMS

SYSTEM DESCRIPTION: Open, random access, counter top instrument for chemical and immunoturbidimetric clinical analysis. METHODOLOGIES: Kinetic, fixed time, end point, immunoturbidimetric, differential. 300+ different methods can be programmed. OPERATIVE MODE: Profile, batch, STAT. THROUGHPUT: 130 tests/hr - 221 tests/hr with the ISE module. SAMPLE LOADING: Continuos loading on 4 separate racks, 8 positions each. STAT samples can be placed at any time in any of the 4 racks and be run immediately. SAMPLE CONTAINERS: Primary tubes (diameter from 6 to 16 mm; height up to 100 mm). Cups from 1 ml to 4 ml. SAMPLING: -Sample volume: 2 to 99 µl (1 µl increments) -Reagent volume: 25 to 400 µl (1 µl increments) -Capacity level sensor -Reagent preheating to 37° C -Automatic sample probe washing (internal and external) -Probe wash cycle is operator programmable. REAGENTS: 24 positions available for reagent containers. STANDARDS AND CONTROLS: Up to 12 positions. MINIMUM REACTION VOLUME: 200 µl. READING CUVETTES: 120 semi-disposable, optic grade cuvettes divided among 6 racks (20 each). OPTIC MODULE: - double beam - 8 interferential filters + 1 position available for an optional filter - narrow band filters 340, 380, 405, 492, 510, 546, 578, 620 (± 2) - FWHM: 10nm ± 2nm - 6V - 10W halogen bulb - optic path lenght: 6 mm - resolution: 0,0005 Abs - linearity: up to 3,500 Abs. REACTION TEMPERATURE: Air bath at 37° C ±0.2 COMPUTER & SOFTWARE SPECIFICATIONS: Minimum specs: - Pentium III, 500 Mhz - RAM Memory: 256 Mb - Hard Disk: 20 Gb - Monitor: SVGA 15" color - Printer: Ink jet - Communication: RS232, USB 1.1/2.0 - Operative System: Windows XP OPTIONAL ACCESSORIES: - Barcode reader (reagents and samples) POWER REQUIREMENTS: - 90 - 230 VAC - 47/63 Hz - 300 W WATER CONSUPTION: About 3 ml/test DIMENSIONS & WEIGHT: - Height:53 cm - Width: 57 cm - Lenght: 75 cm - Weight: 43 Kg OPERATING ENVIRONMENT REQUIREMENTS: Room temperature: 18 to 32° C Relative humidity: 20 to 85%
Tampilkan Lebih Banyak